Common problems with the rapid fuel consumption of the oil pump


Release time:

2026-11-05

1. When excessive oil consumption is detected, the generator manufacturer suggests that one should first check for any oil leakage at the connection points such as the engine body, the gear case cover, the large plate on the rear wheel side, the rear cover, and the cover hood. If there is oil leakage, the manufacturer suggests paying attention to whether the sealing gaskets at each connection point are intact. Damaged sealing gaskets should be replaced. If the sealing gaskets are intact, the manufacturer suggests checking whether the connecting screws at each part are loose. For loose bolts, they can be tightened to the specified torque using a wrench. If the above parts are basically normal and the oil leakage is at the frame position, the manufacturer suggests inspecting the oil pan, with the main inspection points being the front end of the oil pan on the same side as the rear wheel, mostly due to the loosening of the frame bolts, which, under the pull of the triangular belt, rubs against the frame angle iron that protects the oil pan, causing the oil pan to be worn through and form a crack, resulting in oil leakage.

2. The generator manufacturer analyzes that normal wear formed over a long period of engine use or abnormal wear caused by improper maintenance will cause longitudinal scratches on the cylinder liner of the diesel engine, exceeding the specified values for the cylinder diameter and piston side clearance, resulting in a corresponding reduction in the supporting force of the piston ring, and causing insufficient oil scraping. Or due to the internal supporting spring of the oil ring breaking at the opening position, causing insufficient oil scraping and participation in combustion, resulting in severe oil consumption symptoms, manifested as difficulty in starting the diesel engine, obvious blue smoke coming out of the exhaust pipe, and severe oil injection from the air cleaner. The manufacturer's analysis: Furthermore, the piston should be on the upward side, but during assembly, due to the reversed direction, the combustion chamber forms an inverted state. Although it will not affect the starting of the diesel engine, the loss of oil will be quite serious, with a daily fuel consumption of about 0.5 kilograms.

3. The generator manufacturer analyzes that although the situation where the valve guide is severely worn and burns the oil of the diesel generator set is rare, according to relevant information, it is also a reason that cannot be ignored.


Customer service hotline:

Service time:8:00 - 24:00